Manufacturer/Origin
:GMC I-PROSyS/UK
|
Electrical Characteristics
Current Range IN ................................ : 200A ACRMS
Measuring Range ............................... : 0.5A to 300ARMS
Output Sensitivity ................................ : 10mV / A
Load Impedance ................................. : >10kOhm
Conductor Position Sensitivity .............. : <0.5% @ 50/60Hz
Error due to adjacent conductor ........... : ≤15mA / A @ 50Hz
Phase Shift at 2kHz @ 10A ................... : ±1 degree
Frequency Range ............................... : 40Hz to 10kHz (- 3dB)
Temperature Coefficient ....................... : 0.015% / °C
Working Voltage .................................. : 600V ACRMS or DC
(see Safety Standards section)
Accuracy
Primary Current |
0.5 to 10A |
10 to 50A |
50 to 100A |
100 to 300A |
Accuracy
(of rdg) |
± 3% + 0.5mA |
± 2% + 0.5mA |
± 1% + 0.5mA |
± 1% + 0.5mA |
Phase Error |
Not specified |
5° |
2.6° |
2° |
General Characteristics
Maximum Conductor Size ................ : 15mm diameter, bus bar 15 x 17mm
Output Connection .......................... : 4mm safety sockets
Operating Temperature Range .......... : -10 to +55°C
Storage Temperature Range ............. : -20 to +70°C
Operating Humidity .......................... : 15% to 85% (non condensing)
Weight ........................................... : 175g |