CP1010 TRMS
Manufacturer/Origin
:GMC I-PROSyS/UK
|
• AC/DC low current measurement down to mAmps
• Auto ranging 4/40A with 1/10mA resolution (CP41)
• Auto ranging 40/400A with 10/100mA resolution (CP410)
• Auto ranging 400/1000A with 100mA/1A resolution (CP1010)
•·Conformance to IEC1010 and EMC standards
• Auto Zero and Auto Power Off
• Low battery indicator
• Compact lightweight design
High Accuracy
Advanced patented magnetic circuit design results in accuracy to be little affected by external magnetic fields or off-centre conductor positioning.
EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.
TYPICAL APPLICATIONS
• Leakage current measurements (CP41)
• Process control for 4 – 20mA current loop verification (CP41)
• Battery charging systems
• Starting currents
• Light industrial and residential electrical installation testing
|
FREQUENCY RESPONSE ENVIRONMENTAL DATA
DC only DC
AC only 15Hz – 400Hz
DISPLAY
Size and type 4000-count LCD
10mm characters
Status indication Low Battery, Polarity
Refresh rate 2 times per second
MECHANICAL DATA
Dimensions(mm) 194 (H) x 74 (W) x 25 (D)
Jaw Capacity 25mm Ø (CP41/CP410)
32mm Ø (CP1010)
ENVIRONMENTAL DATA
Operating Temperature 0°C to 50°C (32°F to 122°F)
Temperature Coefficient ± 0.15% of reading per °C
(± 0.1% of reading per °F)
Storage Temperature(without battery) -20°C to 85°C (-4°F to 185°F)
SAFETY
EN61010-2-032:2002,
300V, Measurement Category III, Pollution Degree 2.
|