Transducers/Energy Management
Angular Position Transmitter
Process Management/Signal Converter
Shunt
AC/DC Split-core Transducer
Current Probes
Energy Measurement w/ Rogowski
Power Supplies
Connectors
Communication Networks
 

 

N-biz Electronics Home > Product List > Transducers/Energy Management

Transducers/Energy Management


Unifunctional Transducers
Current Transducers
Voltage Transducers
Power Transducers
Frequency and Phase Angle

Analog Display Meters

Multifunctional Transducers
Universal Measuring unit CAM
DM5S & DM5F

Content Displaying Power Meters
All in one APLUS
Voltage Transducers

SINEAX U539
 

SINEAX U539

Manufacturer/Origin:
CamilleBauer/Switzerland

Transducer for alternating voltage

To measure sinusoidal alternating voltages, with power supply connection.

Customer benefit
• Cost-effective measurement of voltages with low harmonic content
• Possibility of adjusting the maximum value of the measuring range on site

Technical data
Meas. input: 0…100 V, 0…250 V, 0…500 V or customised 0…50 V to 0…600 V
Nominal frequency 50/60 Hz
Meas. output: 0…20 mA, 4…20 mA, 4…20 mA 2-wire technology, 0…10 V or customised
Accuracy: Class 0.5 at 15…30 °C, Class 1 if Un >500 V
Power supply: 24 – 60 V AC/DC, 85 – 230 V AC/DC or
24 V, 110 V, 115 V, 120 V, 230 V, 400 V AC 50/60 Hz or
24 V DC or 24 V DC via output circuit in 2-wire technology
H x W x D: 69.1 x 35 x 112.5 mm
 
 
SINEAX U543
 

SINEAX U539

Manufacturer/Origin:
CamilleBauer/Switzerland

Transducer for alternating voltage
To measure sinusoidal alternating voltages, without power supply connection

Customer benefit
• Cost-effective measurement of voltages with low harmonic content
• Without power supply connection, low wiring expenditure

Technical data
Meas. input: Different ranges from 0…100/√3 to 0…500 V or customized
0…20 V to 0…600 V, maximum 300 V nominal value of the system against earth
Nominal frequency 50/60 Hz
Maximum value of the measuring range is fixed or can be set via potentiometer
(approx. ±10%)
Meas. output: 0…1 mA, 0…5 mA, 0…10 mA, 0…20 mA or
0…10 V or customised (0…1 V to 0…<10 V)
Accuracy: Class 0.5 at 15…30 °C
H x W x D: 69.1 x 35 x 112.5 mm

 
 
SINEAX U553
 

SINEAX U554

Manufacturer/Origin:
CamilleBauer/Switzerland

Transducer for alternating voltage

To measure sinusoidal or distorted alternating voltages,
with power supply connection.

Customer benefit
• RMS value measurement up to crest factor 6
• Possibility of adjusting the maximum value of the measuring range on site
• Standard as GL (Germanischer Lloyd), suitable for ships
• Can also be used for 400 Hz systems

Technical data
Meas. input: Different ranges from 0…100/√3 to 0…500 V or customized
0…20 V to 0…690 V, maximum 400 V nominal value of the system against earth
Nominal frequency 50/60 Hz or 400 Hz
Maximum value of the measuring range can be set via potentiometer
(approx. ±15%)
Meas. output: 0…20 mA, 4…20 mA, 0…10 V or customized
0…1 to 0…20 mA or 0.2…1 to 4…20 mA or
0…1 to 0…10 mA or 0.2…1 to 2…10 V
Setting time 50 ms or 300 ms
Accuracy: Class 0.5 at 15…30 °C
Power supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC
(also from measurement input) or
24 V AC / 24 – 60 V DC, connection on the low-voltage side
H x W x D: 69.1 x 70 x 112.5 mm

 

SINEAX U554
 
SINEAX U554
Manufacturer/Origin:
CamilleBauer/Switzerland

Transducer for alternating voltage

To measure sinusoidal or distorted alternating voltages, with power supply connection.

Customer benefit
• RMS value measurement up to crest factor 6
• The measuring range which is of interest can be highlighted

Technical data
Meas. input: Minimum value 0 V, maximum value of the measuring range E3 = 20…690 V,
Step point 0.1 · E3…0.9 · E3
Nominal frequency 50/60 Hz or 400 Hz
Meas. output: Maximum value A3 = 1 mA, 5 mA, 10 mA, 20 mA, 10 V or customised 1…20 mA or 1…10 V

Accuracy: Class 0.5 at 15…30 °C
Power supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC (also from measurement input)
24 V, 110 V, 115 V, 120 V, 230 V, 400 V AC 50/60 Hz or
24 V AC / 24 – 60 V DC, connection