SHUNTS
SIRAX SH100
The shunts are used to measure DC currents, especially at high current levels. The current passing through the shunt produces a proportional voltage drop, which can then be displayed with a moving-coil instrument. The shunts are manufactured in class 0.5 or 0.2 according to DIN 43709 and DIN 60051 with nominal currents in the range from 1A to 15000A and a voltage drop from 50mV to 150mV. Shunts are calibrated in such a way that they produce an accurately defined voltage drop (e.g. 60mV, 150mV).
Features
- Large measuring range from 1A ... 15000A
- Robust construction
- In-line bus bar mounting
- Very low temperature coefficient
- high long term stability
- High overload withstand
- Shock and vibration proof
Application
Dimensional drawings
AC/DC current probes for automotive
|
|
|
Robust Jaws and Housings:
-Mainly for Automotive Production Lines
-Machined Plastic Jaws
-Metal Jaws
-Locking Jaws
-Different Jaws sizes (22, 25, 32 mm)
-Large number of operations
-Hall Effect & Fluxgate Technique |
|
Customised Solutions for Car Diagnosticsand After Market Sales:
-Current and Voltage measurement
-USB versions available
-RF and Bluetooth versions-Stand Alone Solutions with Display
-Optimised Products on custom specific devices |
Hall effect AC/DC current probes overview
-One common probe case
-Battery / Externally powered
-3 Jaw Sizes (25mm, 32mm and 12mm) |
-Open / Closed Loop Hall Effect measurement techniques
-Option for digital display for battery powered versions |
Hall Effect Probes:
|
|
-Open Loop Technique
-Closed Loop Technique
-1 mA Resolution
-DC to 100 kHz
-mA to 2000 A
- CP Series |
- CP30 - 30A 25mm ø DMM
-CP35- 30A 25mm ø OSC
-CP41- 30A 25mm ø Display
-CP60 – 60A 12mm ø DMM
Ø CP61 – 60A 12mm ø Display
|
|
GMC-I |
CP60 |
CP30 |
CP1000 |
Measuring Range(s) |
CP1000 |
60A |
30A |
1000A |
Output |
100mV/A |
10mV/A |
1000mV/A |
1mV/A |
Resolution |
1mA |
10mA |
1mV/A |
500mA |
Accuracy (% of rdg) |
1% |
1% |
1% |
Frequency range |
DC - 100kHz |
DC - 20kHz |
DC - 10kHz |
Output Zero |
AUTO |
AUTO |
AUTO |
Conductor Dia. |
12mm |
25mm |
32mm |
Output connector |
Plugs |
Plugs |
Plugs |
Working voltage |
150V, C I |
300V, C III |
300V, C III |
Battery life |
60 hrs |
30 hrs |
50 hrs |
DISPLAY |
N/A |
N/A |
N/A |
Availability |
DEC '09 |
SEPT '09 |
SEPT '09 |
|
GMC-I
|
CP 35 |
CP 305 |
CP1005 |
30A |
30A |
300A |
100A |
1000A |
100mV/A |
10mV/A |
1mV/A |
10mV/A |
1mV/A |
1mA |
50mA |
100mA |
100mA |
500mA |
1% |
1% |
1% |
DC - 100kHz |
DC - 20kHz |
DC - 20kHz |
AUTO |
AUTO |
AUTO |
25mm |
25mm |
32mm |
BNC |
BNC |
BNC |
300V, C III |
300V, C III |
300V, C III |
30 hrs |
30 hrs |
50 hrs |
N/A |
N/A |
N/A |
SEPT '09 |
NOV '09 |
SEPT '09 |
|
GMC-I
|
CP61 |
CP41 TRMS |
CP410 TRMS |
40A |
60A |
4A |
40A |
40A |
400A |
39,99 |
59,9 |
399,9 |
39,99 |
39,99 |
399,9 |
10mA |
100mA |
1mA |
10mA |
10mA |
100mA |
1,5% |
1,3% |
1% |
DC / 15 - 400Hz |
DC / 15 - 400Hz |
DC / 15 - 400Hz |
AUTO |
AUTO |
AUTO |
12mm |
25mm |
32mm |
Analogue Output |
N/A |
N/A |
150V, C I |
300V, C III |
300V, C III |
30 hrs |
15 hrs |
50 hrs |
4000 count LCD |
4000 count LCD |
4000 count LCD |
MARCH '10 |
SEPT '09 |
DEC '09 |
|
GMC-I
|
CP600A |
CP1000A |
600A
|
1000A
|
1mA/A
|
1mA/A
|
|
|
1% |
1% |
5Hz - 20kHz |
30Hz - 10kHz |
N/A |
N/A |
35mm |
55mm |
Plugs |
Plugs |
1000V, C III |
1000V, C III |
N/A |
N/A |
N/A |
N/A |
MAY '10 |
JUNE '10 |
|
|
AC/DC Multimeter Probes
|
|
AC/DC Oscilloscope Probes
|
|
AC/DC Clamp Meters
|
|
AC Only Current Probes
|
Flexible AC current probes
-2000 hours continuous battery life
-External power supply option
-Increased output sensitivity fromRogowski probe head giving widerdynamic range (measuring range 100 mA to 3000A / 6000A)
-Superior conductor position sensitivity including coupling area
-Improved external field rejection
-Smaller probe diameter (9.9mm) giving easier access to confined areas
-Smaller end cap diameter (13.6mm)
-Range select via robust rotary switch
-IP65 rating - Rogowski Probe Head
-UL Approved, ROHS and WEEE Compliant
-1000V, CAT III, Pollution Degree 2
Flexible Probes with Integrator:
-Single heads / 3 Phase systems
-Battery and/or external power
-PRO~flexACP Range for OEM applications
-METRAFLEX / DRANFLEX as accessories
-Multimeter& Oscilloscope versions
Calibrated Heads:
- Single heads
- Four head bundles
- Interchangeability
- Customised output sensitivity