Isolation
Amplifier
SINEAX TV819 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland
|
Isolation amplifier
for unipolar and bipolar DC currents and voltages
Customer benefit
• Standard and non-standard signals
• Safe isolation, enhanced up to 600 V (Cat. II) or 1000 V (Cat. I)
• Manual zero and span calibration
Technical data
Input: –0.1…+0.1 mA to –40…+40 mA,
–0.06…+0.06 V to –1000…+1000 V
Output: –1…+1 mA to –20…+20 mA, –1…+1 V to –10…+10 V
Power supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC
Height x width x depth: 69.2 x 17.5 x 114 mm (terminals not pluggable)
85 x 17.5 x 114 mm (terminals pluggable) |
|
|
SINEAX TV808-11 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland
|
Configurable isolation amplifier
for unipolar and bipolar DC currents and voltages
Customer benefit
• 36 I/O combinations with jumpers configurable or customised measuring range
• Inputs and outputs for current and voltage in one device
• Intrinsically safe input for signals from hazardous areas
• Manual zero and span calibration
Technical data
Input: 0…20 mA, 4…20 mA, ±20 mA, 0…10 V, 2…10 V, ±10 V
or customised
Output: 0…20 mA, 4…20 mA, ±20 mA, 0…10 V, 2…10 V, ±10 V
or customised
Power supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC
Height x width x depth: 120 x 17.5 x 146.5 mm |
|
|
SINEAX TV808-115 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland
|
Isolation amplifier with HART Protocol
for DC currents and voltages and I/P valve positioner
Customer benefit
• Intrinsically safe output for I/P valve positioner in hazardous areas
• HART pass-through
• Unipolar and bipolar inputs, standard or customised signal
Technical data
Input: –1…+1 mA to –20…+20 mA,
–0.06…+0.06 V to –20…+20 V
Output: 0…20 mA, 4…20 mA, 20…0 mA, 20…4 mA
Power supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC
Height x width x depth: 120 x 17.5 x 146.5 mm |
|
|
SINEAX TV808-12 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland
|
2-channel isolation amplifier
for unipolar and bipolar DC currents and voltages
Customer benefit
• 2 isolated channels or 1 input/2 outputs in 17.5 mm design width
• Manual zero and span calibration
• 252 I/O combinations with solder bridges configurable or customised measuring range
Technical data
Input: Different ranges from 0.06 V to 20 V or 0.1 mA to 20 mA
or customised
Output: 0…20 mA, 4…20 mA, ±20 mA mA or customised
Power supply: 24 – 60 V AC/DC or 85 – 230 V AC/DC
Height x width x depth: 120 x 17.5 x 146.5 mm |
|
|
SINEAX TV810 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland
|
DC current-voltage isolating amplifier
Isolating amplifier DC-signal converter (current/voltage)
Main features
• 3-way galvanic isolation
• Power for 2-wire transducers, 20 V DC
Technical data
Input: Current bipolar setuble up to 20 mA or voltage
Output: Current or voltage
Test voltage: 1.5 kV
Response time: 35 ms
Power supply: 9...40 V DC, 19...28 V AC
Height x width x depth: 100 x 17.5 x 112 mm |
|
|
SINEAX TV804 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland |
DC current isolating amplifier
Isolating amplifier,
DC current isolator
Main features
• 3-way galvanic isolatio
• Power for 2-wire transducers, 20 V DC
Technical data
Input: Current (active or passive)
Output: Current (active or passive)
Test voltage: 500 V
Response time: 40 ms
Power supply: 9...40 V DC, 19...28 V AC
Height x width x depth: 100 x 17.5 x 112 mm |
|
|
SINEAX TVD820 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland |
DC duplicator/isolating amplifier
Isolating amplifier,
DC-signal duplicator (current/voltage)
Main features
• 3-way galvanic isolation
• Screw-fit terminals removable
Technical data
Input: Current or voltage
Output: Current or voltage selectable
Testvoltage: 1.5 kV
Accuracy: 0.2%
Power supply: 19...40 V DC, 19...28 V AC
Height x width x depth: 100 x 17.5 x 112 mm
|
|
|
SINEAX TV829 |
|
|
Manufacturer/Origin:
CamilleBauer/Switzerland |
High-voltage isolation amplifier
for shunt and voltage measurement on high potential
Customer benefit
• Safe galvanic isolation according to DIN EN 61010-1 and DIN EN 50124 (Cat. III)
• High test voltage: 10 kV
• Calibrated range shaft
• High common-mode rejection ratio: 150 dB
Technical data
Input (switch-selectable): ±60 mV, ±90 mV, ±150 mV,
±300 mV, ±500 mV, ±10 V 1
±400 V, ±600 V, ±800 V, ±1000 V, ±1200 V
±1400 V, ±1600V, ±1800V, ±2000 V, ±2200 V, ±3600 V 2
Output (switch-selectable): 4…20 mA, ±20 mA, ±10 V
Power supply: 24 – 253 AC/DC
Height x width x depth: 90 x 22.5 x 118 mm (Article No. 158 312)
90 x 67.5 x 118 mm (Article No. 158 320 and 158 338) |
|
|
|